Aguas SB Observatory · public data to understand water

WWTP Kollund Renseanlæg

Denmark · official identifier DK5030006

10,500h-e design capacity (2022) · 165th of 321

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier DK5030006 · reported size 10,500 h-e design capacity · received load 2,017 h-e · reported treatment: PST · data year 2022. 165th of 321 records with reported size in the inventory of Denmark; 0.09 % of the sum of those 321 records in h-e (sum of records, not national capacity); nearest inventoried plant at 4.7 km · 2 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

10,500h-e design capacity
2,017h-e received load (2022)
19 %reported load/capacity ratio (not hydraulic utilisation)
165th of 321by reported size among the 321 records with a size in the inventory · 0.09 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary + tertiary (more stringent) (as reported to the EEA: PST) · reported levels
Nitrogen removalyes
Phosphorus removalyes
UV disinfectionnot reported
Statusactive
Reported coordinates54.8460, 9.4641 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Denmark

Regulatory framework of Denmark · Directive (EU) 2024/3019: reported-capacity band 10,000 to 149,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

109,533reference kWh per year for this load
55.6kWh per h-e (average load) per year
16,430€ per year at 0.15 €/kWh
63 %share of energy used for aeration

what this estimate is · Inputs: 2,017 p.e. of reported load; equivalent average load 1,971 p.e. with the reference profile of Denmark (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.2estimated hm³ of treated water per year
tertiary treatment reporteda starting point for reclamation

what this estimate is · Volume estimated from the reported load (629 m³/day of reference), not measured or available for reclamation.

LOCATION

Denmark: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Bov Renseanlæg4.7 km19,0004,953primary, secondary and tertiary
Huk8.5 km52,50019,893primary, secondary and tertiary
Broager Vig13.3 km10,0006,748primary, secondary and tertiary
Gårdeby Renseanlæg15.3 km15,00016,664primary, secondary and tertiary
Stenneskær Renseanlæg19.2 km6,0002,606primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP Kollund Renseanlæg report?

Reported size: 10,500 h-e design capacity. Received load: 2,017 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PST. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of Kollund Renseanlæg?

Aguas SB simulator reference scenario for 2,017 p.e. of reported load: 109,533 kWh per year (55.6 kWh per p.e. of average load), with aeration as 63 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.