Worldwide wastewater treatment observatory · France

Aguas SB Observatory · public data to understand water

WWTP CAP SICIÉ - AMPHITRIA

France · official identifier FR060983126001

500,000h-e design capacity (2022) · 18th of 4,051 (tied with 1 others)

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier FR060983126001 · reported size 500,000 h-e design capacity · received load 305,512 h-e · reported treatment: PS · data year 2022. 18th of 4,051 records with reported size in the inventory of France (tied with 1 others); 0.51 % of the sum of those 4,051 records in h-e (sum of records, not national capacity); nearest inventoried plant at 10.0 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

500,000h-e design capacity
305,512h-e received load (2022)
61 %reported load/capacity ratio (not hydraulic utilisation)
18th of 4,051by reported size among the 4,051 records with a size in the inventory (tied with 1 others) · 0.51 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalnot reported
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates43.0495, 5.8514 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

FUENTES PÚBLICAS

What public sources report

Documented milestones

Facts taken from public documents, with their date and link; an authorisation, a project or a planned capacity do not prove operation or quantities actually treated. Aguas SB editorial layer, lot L02; it does not change the official data.

REGULATORY REFERENCES

Referencia normativa: France

Regulatory framework of France · Directive (EU) 2024/3019: reported-capacity band 150,000 p.e. or more; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

8,420,681reference kWh per year for this load
27.5kWh per h-e (average load) per year
1,263,102€ per year at 0.15 €/kWh
66 %share of energy used for aeration

what this estimate is · Inputs: 305,512 p.e. of reported load; equivalent average load 305,663 p.e. with the reference profile of France (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

16.2estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (44,299 m³/day of reference), not measured or available for reclamation.

LOCATION

France: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
La Cride10.0 km60,00045,698primary and secondary
La Garde Pont de la Clue13.9 km106,50064,193primary and secondary
Le Castellet-Le Beausset-la Cadière14.6 km27,00018,968primary, secondary and tertiary
Saint-Cyr-Sur-Mer Pointe Grenier18.2 km35,00017,192primary and secondary
La Crau Vallee Du Gapeau22.2 km80,60044,569primary, secondary and tertiary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP CAP SICIÉ - AMPHITRIA report?

Reported size: 500,000 h-e design capacity. Received load: 305,512 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of CAP SICIÉ - AMPHITRIA?

Aguas SB simulator reference scenario for 305,512 p.e. of reported load: 8,420,681 kWh per year (27.5 kWh per p.e. of average load), with aeration as 66 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.