Worldwide wastewater treatment observatory · Italy
Aguas SB Observatory · public data to understand water
WWTP Pontelongo_Via_Dante
Italy · official identifier IT05000000000254
6,000h-e design capacity (2022) · 1775th of 3,726 (tied with 102 others)
European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier IT05000000000254 · reported size 6,000 h-e design capacity · received load 3,935 h-e · reported treatment: PS · data year 2022. 1775th of 3,726 records with reported size in the inventory of Italy (tied with 102 others); < 0.01 % of the sum of those 3,726 records in h-e (sum of records, not national capacity); nearest inventoried plant at 5.1 km · 2 within 10 km. Reported data with their source; estimates are not measurements of the plant.
Aguas SB does not manage this wastewater treatment plant.
WHAT THE DATA REPORT
Reported data official data · 2022
| Treatment | primary + secondary (as reported to the EEA: PS) · reported levels |
|---|---|
| Nitrogen removal | yes |
| Phosphorus removal | yes |
| UV disinfection | yes |
| Status | active |
| Reported coordinates | 45.2400, 12.0310 precision reported by the source: level 0 what it means |
| Source and year | European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record |
REGULATORY REFERENCES
Referencia normativa: Italy
Regulatory framework of Italy · Directive (EU) 2024/3019: reported-capacity band 1,000 to 9,999 p.e.; obligations are set by agglomeration load, not by the capacity of this plant. Individual applicability is not determined in this profile.
SCENARIO
Reference energy scenario for this load estimate · simulator engine
what this estimate is · Inputs: 3,935 p.e. of reported load; equivalent average load 2,715 p.e. with the reference profile of Italy (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.
Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.
WATER THAT COULD RETURN
Reuse potential
what this estimate is · Volume estimated from the reported load (787 m³/day of reference), not measured or available for reclamation.
NEARBY PLANTS
Nearby wastewater treatment plants
| Plant | Distance | Capacity (h-e) | Load 2022 | Treatment |
|---|---|---|---|---|
| Cona_pegolotte | 5.1 km | 6,000 | 3,504 | primary and secondary |
| Codevigo_via_altipiano | 6.0 km | 65,000 | 46,401 | primary and secondary |
| Agna_via_cimitero | 10.1 km | 6,200 | 3,025 | primary, secondary and tertiary |
| Conselve_via_dell_industria_zi | 11.0 km | 46,880 | 28,686 | primary, secondary and tertiary |
| Casalserugo_via_l_da_vinci | 11.8 km | 5,000 | 4,564 | primary, secondary and tertiary |
Distances are between reported coordinates; proximity does not establish a hydraulic connection.
QUESTIONS
Frequently asked questions about this plant
What capacity does WWTP Pontelongo_Via_Dante report?
Reported size: 6,000 h-e design capacity. Received load: 3,935 h-e. Units are retained without conversion.
What treatment is reported?
Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.
How much energy would a reference plant use with the load of Pontelongo_Via_Dante?
Aguas SB simulator reference scenario for 3,935 p.e. of reported load: 141,148 kWh per year (52.0 kWh per p.e. of average load), with aeration as 66 % of consumption. Estimate with the country reference profile; not a measurement of the plant.
SOURCE AND CORRECTIONS
Source
reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.