Worldwide wastewater treatment observatory · Switzerland

Aguas SB Observatory · public data to understand water

WWTP LA SAGNE

Switzerland · official identifier CH_WWTP_642300

975h-e design capacity (2022) · 541st of 705

European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · official identifier CH_WWTP_642300 · reported size 975 h-e design capacity · received load 791 h-e · reported treatment: PS · data year 2022. 541st of 705 records with reported size in the inventory of Switzerland; < 0.01 % of the sum of those 705 records in h-e (sum of records, not national capacity); nearest inventoried plant at 5.7 km · 4 within 10 km. Reported data with their source; estimates are not measurements of the plant.

Aguas SB does not manage this wastewater treatment plant.

WHAT THE DATA REPORT

Reported data official data · 2022

975h-e design capacity
791h-e received load (2022)
81 %reported load/capacity ratio (not hydraulic utilisation)
541st of 705by reported size among the 705 records with a size in the inventory · < 0.01 % of the sum of those records (sum of records, not national capacity) · the largest plants in the country · how it is calculated
Treatmentprimary + secondary (as reported to the EEA: PS) · reported levels
Nitrogen removalnot reported
Phosphorus removalnot reported
UV disinfectionnot reported
Statusactive
Reported coordinates47.0329, 6.7940 precision reported by the source: level 2 what it means
Source and yearEuropean Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · dataset record

REGULATORY REFERENCES

Referencia normativa: Switzerland

Regulatory framework of Switzerland. Individual applicability is not determined in this profile.

SCENARIO

Reference energy scenario for this load estimate · simulator engine

50,775reference kWh per year for this load
56.8kWh per h-e (average load) per year
7,616€ per year at 0.15 €/kWh
58 %share of energy used for aeration

what this estimate is · Inputs: 791 p.e. of reported load; equivalent average load 894 p.e. with the reference profile of Switzerland (hypothesis with reported load and reference profile; not a measurement). Open this scenario in the simulator · how it is calculated and what it is not.

Reference scenario computed on the server from the reported load and the country profile; an estimate, not a measurement. The simulator recomputes it when opened.

WATER THAT COULD RETURN

Reuse potential

0.1estimated hm³ of treated water per year
tertiary treatment not reportedreclamation requires additional treatment

what this estimate is · Volume estimated from the reported load (267 m³/day of reference), not measured or available for reclamation.

LOCATION

Switzerland: this plant on the map

this plant on the map · regional directory.

NEARBY PLANTS

Nearby wastewater treatment plants

PlantDistanceCapacity (h-e)Load 2022Treatment
Le Locle5.7 km20,0009,234primary and secondary
Les Ponts-de-Martel6.6 km2,000979primary and secondary
Les Brenets8.2 km2,500798primary and secondary
Colombier(La Saunerie)9.2 km32,00028,156primary and secondary
Noiraigue10.2 km700424primary and secondary

Distances are between reported coordinates; proximity does not establish a hydraulic connection.

QUESTIONS

Frequently asked questions about this plant

What capacity does WWTP LA SAGNE report?

Reported size: 975 h-e design capacity. Received load: 791 h-e. Units are retained without conversion.

What treatment is reported?

Treatment PS. Nitrogen, phosphorus and UV are shown only when explicitly reported.

How much energy would a reference plant use with the load of LA SAGNE?

Aguas SB simulator reference scenario for 791 p.e. of reported load: 50,775 kWh per year (56.8 kWh per p.e. of average load), with aeration as 58 % of consumption. Estimate with the country reference profile; not a measurement of the plant.

SOURCE AND CORRECTIONS

Source

reported data · European Environment Agency — Waterbase-UWWTD, data call 2023 (versión final pública) · data 2022 · edition 2023 · source licence: CC BY 4.0 · JSON for this plant · suggest a correction · catalogue 2026-11-06. Reported data, not a current inspection; no compliance judgements.